No title
Question:
What is Error Code 81E or 81C and how can it
be resolved?
Answer:
Error Code 81E or 81C refers to compressor
starting failure. This issue may occur due to an abnormality in the Inverter
PCB IPM operation (with voltage lower than DC 13.5V) or a short circuit in the
compressor. To resolve this issue, first check the power supply to ensure proper
voltage. If the voltage is stable, then check the compressor for any potential
short circuits. After identifying and fixing the problem, try starting the compressor
again.
Terms:
Error Code (refers to a specific message indicating
a problem or issue)
Inverter PCB IPM (abbreviation for Inverter
Printed Circuit Board Intelligent Power Module, responsible for power conversion
and control)
Voltage (electrical force or pressure provided
by a power source)
DC 13.5V (Direct Current at 13.5 volts, a standard
voltage level)
Compressor (a device used to compress refrigerant
in an air conditioning system)
Short Circuit (an unintended electrical connection
between two points in an electrical circuit)
|